Skip to content Skip to footer
Certifications and compliance

The standard
is what counts.

What counts is the standard: UL 1598 for luminaires, UL 844 for hazardous locations. Who tested it —UL or Intertek— is secondary: both are NRTLs and both test against the same standard. Here is the full catalog, series by series, no fine print.

UL 1598
Product standard
across the certified catalog
UL 844
Hazardous locations
Class I Div 2 · Class II · T3
US·CA·MX
All of North America
UL · ETL / cETL · NOM
24 h
To send you the documentation
for the series you need
Our files

Two UL files and five ETL listings, verifiable today

All under Jungo Industries SAPI de CV. Copy them and look them up yourself in the public UL and Intertek directories — you do not need to ask us.

UL Certified
UL Solutions
E497790
CCN
IFAM
Category
Light-emitting-diode Surface-mounted Luminaires
Holder
Jungo Industries SAPI de CV
Covers
High bay, low bay, area light, wall pack, flood, tri-proof and other surface-mounted luminaires
Verify in UL Product iQ ↗
UL Certified
UL Solutions
E505095
CCN
IFAO
Category
Light-emitting-diode Recessed Luminaires
Holder
Jungo Industries SAPI de CV
Covers
Panel and Smart Panel — recessed luminaires
Verify in UL Product iQ ↗
Intertek
5 listings
Intertek does not publish a file number. Verification is by company name and model in the Directory of Listed Products.
UL-1598
Luminaires — ETL mark (USA)
C22.2 250.0
Luminaires — cETL mark (Canada)
UL-844
Hazardous locations — ETL mark (USA)
C22.2 No. 137
Hazardous locations — cETL mark (Canada)
UL-1598A
Marine vessels — Besser Lighting mark
Verify in the Intertek Directory ↗
Mexican Official Standards
Current
NOM-003-SCFI
Electrical safety of products
NOM-031-ENER
Energy efficiency of LED luminaires
Request NOM certificates →
Quick guide

UL, ETL and NOM: what each one is and which one you will be asked for

Confusing these three is the number-one reason a project submittal gets sent back. Here is the short version.

01

UL

Underwriters Laboratories · NRTL

Nationally recognized testing laboratory in the United States. It tests against the standard and assigns a public file number. Our files: E497790 (surface-mounted) and E505095 (recessed), both under UL 1598.

  • UL 1598 — general product standard
  • UL 844 — hazardous locations (HazLoc)
  • UL 1598A — marine vessels, not HazLoc
02

ETL

The mark Intertek certifies under

It is the mark Intertek certifies under, and Intertek is also an NRTL. Same standard, same OSHA recognition. It does not publish a file number: verification is by company and model in its directory. cETL is the Canadian variant.

  • Same standard, same OSHA recognition
  • cETL = the Canadian variant
  • Verified by company and model, not by file
03

NOM

Mexican Official Standard · mandatory

It is neither optional nor “the Mexican equivalent of UL”. It is a legal requirement to sell in Mexico and the first thing reviewed in public tenders and government work.

  • NOM-003-SCFI — electrical safety
  • NOM-031-ENER — LED energy efficiency
  • Both apply to our entire catalog

“UL is worth more than ETL” is false.

Both are NRTLs and both test against the same standard: UL 1598. That is why the column that matters in our table is the standard, not the lab. If a supplier tells you one is worth more than the other, either they do not know or they are selling you something. What does matter is that the exact model you are buying is covered.

By project type

Which certification you will be asked for

Find your case and you will know exactly what documentation to prepare before anyone asks for it.

Case 01

Industrial plant, distribution center or standard commercial building

You will be asked for
  • UL 1598 or equivalent ETL
  • NOM-003-SCFI
  • NOM-031-ENER
  • IES photometric file
This is the vast majority of projects. Practically the whole Jungo catalog falls here, under file E497790.
Case 02

Hazardous location — mining, oil & gas, chemical, fuel station canopy

This is how we have it certified
  • UL-844 (ETL) y C22.2 No. 137 (cETL)
  • Class I Div 2, Groups A, B, C, D
  • Class II Div 1 (E,F,G) and Div 2 (F,G); Class III
  • T3 code · from -40 °C to 55 °C depending on model
Full HazLoc catalog: A, B, FLF, H, O and R series for Class I Div 2; C, D, I, HT and EXS for Class I Div 1. A standard luminaire is not an option here, not even with a high IP rating: IP66 does not replace HazLoc.
Case 03

Public tender, government project or municipal street lighting

You will be asked for
  • Current NOM-003-SCFI
  • Current NOM-031-ENER
  • Certificate issued to the manufacturer
  • Local content letter
We manufacture in Monterrey, so the certificate is issued to the manufacturer and not to an importer. That simplifies the submittal.
Quick reference

Certification by series

Full catalog, in the same order as the site menu, with IP/IK ratings taken from each datasheet. The column that matters is the standard. Where UL certified, we give you the file number; where Intertek certified it shows as ETL — its directory does not publish file numbers, so verification is by company and model.

SeriesStandardCertified byNOM-003NOM-031IP / IK
INDOOR
High Bay
Venus Gen 5UL 1598UL · E497790IP65 · IK08
OrionUL 1598UL · E497790IP44 · IK08
Clean PlusUL 1598UL · E497790IP69 · IK08
Low Bay
Canopynot declaredIP65 · IK08
Tri-Proof V2UL 1598ETLIP65 · IK09
NovaUL 1598ETLIP66
Nova WideUL 1598ETLIP66
Strip LineSL-2FT / 4FT / 8FT · BSLMUL 1598ETLIP20
Panels & Troffers
Smart PanelJungo ConnectUL 1598UL · E505095IP40 · IK08
PanelUL 1598UL · E505095IP40 · IK08
Architectural & Interior
Linear LightUL 1598UL · E497790IP20
Flex Down LightFD-6 · FD-8UL 1598ETLIP54
Dual Head LightUL 1598UL · E497790IP20
Dual Head Light with SignUL 1598UL · E497790IP65 · IK08
OUTDOOR
Area & Roadway
Area Light GEN 2UL 1598UL · E497790IP66 · IK08
Wallstreet Lightnot declaredIP66 · IK08
Sidewalknot declaredIP66 · IK10
Wall Mounted
Wall Pack IndustrialUL 1598UL · E497790IP65
Wall Pack ArchitecturalUL 1598UL · E497790IP65
Wall Pack EdgeUL 1598UL · E497790IP65
Loading Docknot declaredIP65 · IK08
Flood & Sports
Flood Light V4not declaredIP66 · IK08
StadiumUL 1598UL · E497790IP66 · IK08
SportUL 1598UL · E497790IP66 · IK08
Lumimaxnot declaredIP66 · IK08
Solar Lighting
Solar AIOnot declaredIP65 · IK10
Solar V4not declaredIP65
Sidewalk Solarnot declaredIP66 · IK10
HAZLOC
Class I Division 2
A SeriesUL 844ETLIP66 · IK08
B SeriesUL 844ETLIP66 · IK08
FLF SeriesUL 844ETLIP66 · IK10
H SeriesUL 844ETLIP66 · IK08
O SeriesUL 844ETLIP66 · IK10
R SeriesUL 844ETLIP66 · IK08
Class I Division 1
C SeriesUL 844ETLIP66 · IK10
D SeriesUL 844ETLIP66 · IK10
I SeriesUL 844ETLIP66 · IK08
HT SeriesUL 844ETLIP66 · IK09
EXS02AUL 844ETLIP66 · IK08
EXS02BUL 844ETLIP66
EXS03AUL 844ETLIP66 · IK08
EXS03BUL 844ETLIP66 · IK08
UL 1598 Product standard · UL 844 hazardous locationsUL · E497790 our UL fileETL certified by Intertek — the directory does not publish file numbersnot declared the datasheet does not declare NRTL certification
How to verify

Three steps so you never end up with an uncertified product

Use it with us and with any supplier. If someone cannot get you past step 1, the conversation ends there.

Ask about the standard

Do not ask “is it UL?”. Ask which standard it is certified against: UL 1598 for general luminaires, UL 844 for hazardous locations. Then ask for the file number (UL) or the name it is listed under (ETL).

Look it up in the directory

UL is verified in Product iQ by file number. Intertek is verified in its Directory of Listed Products by company name or model — there is no file number there. Both are public and free.

Confirm that your model is listed

This is the step almost nobody takes. A file can be active and still not cover the exact model you are being quoted. Verify the model, not the brand.

Frequently asked questions

What we get asked most

Why are some series UL and others ETL?

Because they are different laboratories certifying against the same standard. Both are OSHA-recognized NRTLs. Where it says UL 1598, it meets UL 1598 — no matter which of the two tested it.

Are all Jungo luminaires certified?

No. It applies by series and by model, not by brand. Check the table or ask us for the documentation of the specific series you are quoting.

Does IP66 replace a HazLoc certification?

No. IP measures dust and water ingress. HazLoc certifies that the luminaire cannot start an ignition in a potentially explosive atmosphere. They are different tests and one does not replace the other.

Does the smart version change the certification?

The Jungo Connect version is certified the same as the standard version under its corresponding file. If your submittal needs the detail of the control module, we send it separately.

Can you issue the certificate in the name of my project?

The certificate is always issued to the manufacturer — that is how it works. What we do give you is a compliance letter referenced to your project and to the models quoted.

How long does it take to send me the documentation?

The same business day. Files, NOM certificates, IES files and the datasheet in a single email.

Do you manufacture in Mexico or import?

We manufacture in Monterrey. That is why the NOM certificates are in our name as the manufacturer and not in the name of an importer — which saves you steps in public tenders.

Do you need the file for a specific series for your submittal?

Tell us which series and for which project. We will send you the file, the NOM certificates and the IES file the same business day.

Jungo Lighting® es una marca de Jungo Industries, S.A.P.I. de C.V. · Monterrey, Nuevo León, México Jungo Lighting® is a brand of Jungo Industries, S.A.P.I. de C.V. · Monterrey, Nuevo León, Mexico